TM 9-2320-364-34-2
6-382
6-37. POLARITY POWER WIRE HARNESS REPLACEMENT (200 AMP) (CONT).
(11) Position screw (9), washer (8), cable 1137 (7), cable 1139 (6), cable 1281A (5), cable 1281A (4), washer
(3), lockwasher (2) and nut (1) on positive terminal (10).
While applying torque to nut, hold screw with wrench or damage to battery may occur.
(12) Tighten nut (1) to 12 to 16 lb-ft (16-22 N.m).
Corrosion compound contains alkali. Do not get in eyes; wear goggles/safety glasses when
using. Avoid contact with skin. In case of contact, immediately wash area with soap and
water. If eyes are contacted, flush eyes with large amounts of water at least 15 minutes and
get immediate medical attention.
(13) Apply corrosion preventative compound to positive terminal (10) and positive terminal (19).
c.
Follow-On Maintenance:
Install left side noise panel, (TM 9-2320-364-20).
Connect batteries, (TM 9-2320-364-20).
Remove wheel chocks, (TM 9-2320-364-10).
END OF TASK
9
6
7
8
10
3
2
5
4
1
19
10
|