6-38. POLARITY WIRE HARNESS REPLACEMENT (200 AMP) (CONT).
b.
Installation.
NOTE
Install cable ties as required.
(1)
Position 200 AMP polarity wire harness
(39) in truck.
(2)
Remove nut (142) from terminal (145) of 24
volt solenoid switch (133).
(3)
Install wire 1435 (144), lockwasher (143)
and nut (142) on terminal (145).
(4)
Remove nut (138) from terminal (141) of 24
volt solenoid switch (133).
(5)
Install wire 1021A (140), lockwasher (139)
and nut (138) on terminal (141).
(6)
Remove nut (134) from terminal (137) of 24
volt solenoid switch (133).
(7)
Install wire 1045 (136), lockwasher (135)
and nut (134) on terminal (137).
(8)
Remove nut (129) from terminal (132) of 24
volt solenoid switch (133).
(9)
Install wire 1055 (131), lockwasher (130)
and nut (129) on terminal (132).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a
well-ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water.
(10) Apply electrical sealant to terminal (132),
terminal (137), terminal (141) and terminal
(145).
139
138
140
141
133
142
143
144
39
145
130
131
132
134
135
136
137
129
133
|