| |
TM 9-2320-364-34-2
6-398
6-38. POLARITY WIRE HARNESS REPLACEMENT (200 AMP) (CONT).
(26)
Install 200 AMP polarity wire harness (39) in cushion clip (82).
(27)
Position cushion clip (82) on bracket (83) and secure with screw (81) and locknut (80).
(28)
Install washer (76), wire 1020B (77) and
locknut (75) on terminal (78) of regulator
(79).
(29)
Tighten locknut (75) to 25 lb-in (3 Nm).
78
76
77
79
75
82
83
81
80
39
|