TM 9-2320-364-34-2
6-418
6-39. GENERAL WELDING MAINTENANCE (CONT).
NOTE
If equipped with 145 amp
alternator, perform Steps (4)
through (12).
If equipped with 200 amp
alternator, perform Steps
(13) through (24).
(4)
Install two wires 1435 (126), black wire
(125), lockwashers (124) and nut (123) on
ground stud (127) of DUVAC controller
(107).
(5)
Install two wires 1020 (121), brown wire
(120), lockwasher (119) and nut (118) on
ignition stud (122) of DUVAC controller
(107).
(6)
Install wire 1274 (114), orange wire (115),
red wire (116), lockwasher (113) and nut
(112) on 12 volt battery stud (117) of
DUVAC controller (107).
(7)
Install wire 1278 (110), lockwasher (109)
and nut (108) on 24 volt alternator stud
(111) of DUVAC controller (107).
(8)
Install wire 1277 (105), lockwasher (104)
and nut (103) on 24 volt battery stud (106)
of DUVAC controller (107).
Adhesives, solvents, and sealing
compounds can burn easily can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a
well-ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water.
(9)
Apply electrical sealant to 24 volt battery
stud (106), 24 volt alternator stud (111), 12
volt battery stud (117), ignition stud (122)
and ground stud (127)
|