TM 9-2320-364-34-2
6-420
6-39. GENERAL WELDING MAINTENANCE (CONT).
(13)
Install wire 1430 (92), wire 1079 (91), wire
1075 (90), wire 1866 (89), wire 240/241 (88),
lockwasher (87) and nut (86) on 12 volt load
terminal (93) of polarity protection controller
(76).
(14)
Install wire 1566 (84), lockwasher (83) and
nut (82) on 12 volt battery terminal (85) of
polarity protection controller (76).
(15)
Install wire 1281 (80), wire 1431 (79),
lockwasher (78) and nut (77) on 24 volt load
terminal (81) of polarity protection controller
(76).
(16)
Install wire 1281A (74), lockwasher (73) and
nut (72) on 24 volt battery terminal (75) of
polarity protection controller (76).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a
well-ventilated area. If adhesive,
solvent, or sealing compound gets
on skin or clothing, wash
immediately with soap and water.
(17)
Apply electrical sealant to 24 volt battery
terminal (75), 12 volt load terminal (93),
12 volt battery terminal (85), 24 volt load
terminal (81).
78
76
79
73
77
72
74
75
76
92
90
89
88
91
86
87
83
82
93
81
80
85
84
|