TM 9-2320-364-34-2
6-421
(18)
Install wire 1275 (70), wire 1435 (69), wire
1815 (68), lockwasher (67) and screw (66)
on alternator (71).
(19)
Tighten screw (66) to 17 lb-ft (23 N.m).
(20)
Install wire 1281A (64), wire 1820/1953
(63), fuse link (61) with insulator washer
(62), washer(s) (if removed) (60), washer
(59), lockwasher (58) and nut (57) on 24
volt terminal (65).
(21)
Tighten nut (57) to 15 lb-ft (20 N.m).
(22)
Install wire 1274 (55), wire 1860 (54),
washer (53), lockwasher (52) and nut (51)
on 12 volt terminal (56).
(23)
Tighten nut (51) to 15 lb-ft (20 N.m).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a
well-ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water.
(24)
Apply electrical sealant to screw (66), 12
volt terminal (56) and 24 volt terminal (65).
55
53
52
51
58
64
59
63
61
57
60
60
56
65
67
70
69
68
66
71
54
62
|