TM 9-2320-364-34-3
16-147
(4)
Remove two nuts (10), lockwashers (11),
washers (12), screws (13), washers (14) and
two way hydraulic solenoid valve (15) from
bracket (16). Discard lockwashers.
b.
Disassembly.
Do not damage electrical
connector, or crane will not
operate properly.
(1)
Position two way hydraulic solenoid
valve (1) in vise with soft jaws.
NOTE
Tag and mark fittings and elbows
prior to disassembly.
(2)
Remove elbow (2) and preformed
packing (3) from two way hydraulic
solenoid valve (1). Discard preformed
packing.
|