TM 9-2320-364-34-3
16-148
16-23. TWO WAY HYDRAULIC SOLENOID VALVE REPAIR (CONT).
NOTE
Matchmark data plate and coil
before disassembly.
(3)
Remove nut (4) and data plate (5) from two
way hydraulic solenoid valve (1).
(4)
Remove coil (6) from valve stem (7).
(5)
Remove valve stem (7) from two way
hydraulic solenoid valve (1).
(6)
Remove preformed packings (8) and (9) and
backup ring (10) from valve stem (7).
Discard preformed packings and backup
ring.
(7)
Remove fitting (11) and preformed
packing (12). Discard preformed packing.
c.
Cleaning/Inspection.
Drycleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles, face
shield, and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when
using solvent. The flashpoint for Type II Drycleaning Solvent is 140 degrees F (60 degrees
C) and Type III Drycleaning Solvent is 200 degrees F (93 degrees C). Failure to do so may
result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts
eyes, immediately flush eyes with water and get immediate medical attention.
(1)
Wash parts in drycleaning solvent.
(2)
Dry parts with cleaning cloth.
(3)
Inspect parts for cracks, broken terminals and stripped threads.
(4)
Replace damaged parts.
|