TM 9-2320-364-34-3
16-149
d.
Assembly.
(1)
Apply hydraulic oil to preformed
packing (12).
(2)
Install preformed packing (12) and
fitting (11) in two way hydraulic solenoid
valve (1).
(3)
Apply hydraulic oil to preformed
packing (3).
(4)
Align and install preformed packing (3)
elbow (2).
(5)
Apply hydraulic oil to preformed
packings (8) and (9).
(6)
Install two preformed packings (8) and (9)
and backup ring (10) on valve stem (7).
(7)
Install valve stem (7) in two way hydraulic
solenoid valve (1).
(8)
Install coil (6), data plate (5) and nut (4).
e.
Installation.
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in well-
ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and
water.
(1)
Apply sealing compound to threads of two
screws (13).
(2)
Install two way hydraulic solenoid
valve (15) on bracket (16) with two
screws (13), washers (14), washers (12),
lockwashers (11) and nuts (10). Tighten
nuts to 108 lb-in (12 N.m).
|