TM 9-2320-364-34-3
16-205
NOTE
Perform Step (7) if data plate was
removed.
(7)
Install data plate (36) with four rivets (35).
(8)
Install cap and chain assembly (2) on
bracket (6).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in well-
ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and
water.
(9)
Apply sealing compound on threads of four
screws (32).
(10)
Install brackets (6) and (13) on two function
control valve bank (34) with four
lockwashers (33) and screws (32). Tighten
screws to 72 lb-in (8 N.m).
(11)
Apply sealing compound on threads of four
screws (30).
(12)
Install brackets (6) and (13) on crane
subframe (31) with four screws (30),
washers (29), lockwashers (28) and
nuts (27). Tighten nuts to 17 lb-ft
(23 N.m).
|