TM 9-2320-364-34-3
16-211
(5)
Remove nut (8) and lockwasher (9). Discard lockwasher.
(6)
Remove connector (7) from bracket (10).
b.
Disassembly.
(1)
Remove connector cap (1), ring (2),
grommet (3) and connector (4) from
conduit (5).
(2)
Remove conduit (5) from receptacle
connector body (6) and slide down cable (7)
NOTE
Tag and mark wires before
disassembly.
(3)
Remove 14 wires (8) from receptacle
connector body (6).
NOTE
Perform Step (4) if pins are
damaged.
(4)
Remove 14 pins (9) from wires (8).
(5)
Remove conduit (5), connector (4),
grommet (3), ring (2) and connector cap (1)
from cable (7).
|