TM 9-2320-364-34-3
17-28
17-3. MAIN HYDRAULIC PUMP INPUT SHAFT SEAL REPLACEMENT (CONT).
Use care when installing retaining rings. Retaining rings are under tension and can act as
projectiles when released and could cause severe eye injury.
(3)
Install retaining ring (12) in second groove on main hydraulic pump shaft (11).
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and
are harmful to skin and clothing. To avoid injury or death, keep away from open fire and use
in well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing,
wash immediately with soap and water.
(4)
Apply sealing compound to threads of main hydraulic pump shaft (11).
(5)
Install key (10) end yoke (4), washer (9) and nut (8) on main hydraulic pump shaft (11).
(6)
While holding end yoke (4) with pipe wrench, tighten nut (8) to 138 lb-ft (187 N.m).
|