TM 9-2320-364-34-3
17-51
(5)
Position drain pan under solenoid valve (11).
(6)
Remove solenoid valve (11) from hydraulic manifold (12).
(7)
Remove preformed packing (13), two backup rings (14) and preformed packing (15) from solenoid
valve (11). Discard preformed packings and backup rings.
b.
Installation.
(1)
Coat preformed packings (13) and (15) and two backup rings (14) with hydraulic oil.
(2)
Install preformed packing (15), two backup rings (14) and preformed packing (13) on solenoid valve (11).
(3)
Install solenoid valve (11) in manifold (12) and tighten to 20 lb-ft (27 N.m).
|