TM 9-2320-364-34-3
18-32
18-3. ALTERNATOR KIT INSTALLATION (200 AMP) (CONT).
NOTE
1020 wires in steps (44) through
(48) are part of chassis wire harness
and were removed in Step (1).
(44)
Set multimeter select switch to Ohms.
(45)
Connect positive (+) multimeter lead to
wire 1020 (80) that was removed from
DUVAC IGN terminal.
(46)
Connect negative () multimeter lead to
one of the 1020 wires (81) that were
removed from circuit breaker (82).
(47)
Connect negative () multimeter lead to
remaining wire 1020 (81) from circuit
breaker (82).
(48)
Tie back and tape off wire 1020 (81)
removed from circuit breaker (82) and wire
1020 (80) from DUVAC IGN terminal that
had continuity.
(49)
Install remaining wire 1020 (81) from
chassis wire harness (83) to circuit breaker
(82) with screw (84) and lockwasher (85).
(50)
Install wire 1020A (86) and wire 1020 (87)
of 200 AMP polarity wire harness (23),
lockwasher (88) and screw (89) on circuit
breaker (82).
83
84
89
86
80
87
88
82
85
82
81
81
23
|