18-3. ALTERNATOR KIT INSTALLATION (200 AMP) (CONT).
(66)
Remove locknut (122) and washer (123)
from terminal (124) of regulator (125).
(67)
Install wire 1020B (126) of 200 AMP
polarity wire harness (23), washer (123)
and locknut (122) on terminal (124).
(68)
Tighten locknut (122) to 25 lb-in. (3 N.m).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a
well-ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water.
(69)
Apply electrical sealant to screw (113), 12
volt terminal (101), 24 volt terminal (110)
and terminal (124).
23
125
123
124
126
122
110
113
124
101
|