TM 9-2320-364-34-3
18-41
(99)
Push two wires 240 (180) and (181) and
two wires 241 (182) and (183) and MC14
connector (184) through grommet (185) on
ECB (158).
(100)
Connect MC14 connector (184).
(101)
Connect wire 241 (183) on circuit breaker
CB22 (186).
(102)
Install wire 241 (182) on circuit breaker
CB22 (186) with lockwasher (187) and
screw (188).
(103)
Connect wire 240 (181) on circuit breaker
CB23 (189).
(104)
Install wire 240 (180) on circuit breaker
CB23 (189) with lockwasher (190) and
screw (191).
188
187
191
189
185
186
181
184
183
180
190
158
182
|