TM 9-2320-364-34-3
18-263
(165)
Position four isolators (221) on ECM (222).
(166)
Install ECM (222) on ECM bracket (223)
with four isolators (224) and screws (225).
Tighten screws to 60 to 84 lb-in (7 to 9
N.m).
(167)
Install communication protective cover
(226) on ECM (222).
Adhesive, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a
well-ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water.
(168)
Coat threads of five screws (227) with
antiseize compound.
(169)
Remove backing (228) from DDEC III data
plate (229).
(170)
Install engine cold plate (230), heat shield
(231), and DDEC III data plate (229) on
ECM (222) with five screws (227).
Tighten five screws to 180 lb-in (20 N.m).
(171)
Install two fittings (232) and preformed
packings (233) on fitting (234).
|