TM 9-2320-364-34-4
20-339
(29)
Install water temperature gage sensor (75), fan control sensor (77) and water temperature sending unit
(71) in left thermostat housing (72).
(30)
Connect MC61 connector (76).
(31)
Remove nut (67) from water temperature sending gage sensor (75).
NOTE
Ensure remaining washers in above illustration are still on water temperature sending gage
sensor and water temperature sending unit.
(32)
Install washer (74), washer (70), wire 1320 (73) and lockwasher (68) and nut (67) on water temperature
sending gage sensor (75).
(33)
Remove nut (67) from water temperature sending unit (71).
(34)
Install washer (70), wire 1147 (69) and lockwasher (68) and nut (67) on water temperature sending unit
(71).
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and
are harmful to skin and clothing. To avoid injury or death, keep away from open fire and use
in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing,
wash immediately with soap and water.
(35)
Coat threads of temperature switch (79) and reducer bushing (80) with sealing compound.
(36)
Install reducer bushing (80) in left thermostat housing (72).
(37)
Install temperature switch (79) in reducer bushing (80).
(38)
Connect MC128 connector (78).
|