TM 9-2320-364-34-4
20-345
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and
are harmful to skin and clothing. To avoid injury or death, keep away from open fire and use
in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing,
wash immediately with soap and water.
NOTE
Perform Steps (62) through (64) for DDEC II engines.
Perform Steps (65) through (72) for DDEC III engines.
(62)
Coat threads of reducer (27) and water temperature sensor (26) with sealing compound.
(63)
Install reducer (27) in right thermostat
(64)
Install water temperature sensor (26) in
(65)
Apply sealing compound to threads of
bushing reducer (30).
(66)
Install bushing reducer (30) in thermostat
housing (28).
(67)
Apply sealing compound to threads of
STE/ICE sensor (29).
(68)
Install STE/ICE sensor (29) in bushing
reducer (30).
|