TM 9-2320-364-34-4
23-60
23-12. TORQUE CONVERTER HOUSING REPAIR (CONT).
(19)
Lubricate two driven gears (16) with
hydraulic oil.
(20)
Install two driven gears (16) on shafts (17).
(21)
Lubricate drive gear (15) with hydraulic
oil.
(22)
Install drive gear (15) in oil pump (10).
(23)
Install pump cover (14) and screw (13) on
oil pump (10). Make sure pump cover is
seated and tighten screw to 108 to 132 lb-in
(12 to 15 N.m).
NOTE
Maximum clearance for Step (24)
is 0.006 in. (0.152 mm).
(24)
Check clearance between pump cover (14),
drive gear (15) and driven gears (16) using
feeler gages. If clearance exceeds
specification, replace oil pump.
(25)
Turn oil pump over and apply hydraulic oil
to rubber lip of seal ring (19).
(26)
Using installer and handle, install seal
ring (19) in oil pump (10).
(27)
Turn oil pump over and coat outer seal
ring (12) with hydraulic oil.
(28)
Install seal ring (12) in groove on oil
pump (10).
|