TM 9-2320-364-34-4
24-29
b.
Cleaning/Inspection.
Drycleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles, face
shield, and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when
using solvent. The flashpoint for Type II Drycleaning Solvent is 140 degrees F (60 degrees
C) and Type III Drycleaning Solvent is 200 degrees F (93 degrees C). Failure to do so may
result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts
eyes, immediately flush eyes with water and get immediate medical attention.
(1)
Clean all components with drycleaning solvent and allow to air dry.
(2)
Inspect all components for wear, cracks, warpage, chips, gouges and stripped threads.
(3)
Replace damaged components.
c.
Assembly.
Front housing weighs 200 lbs
(91 kg). Attach suitable lifting
device before removal to prevent
possible injury to personnel.
NOTE
Perform Steps (1) through (4)
only if front housing was
removed.
(1)
Install transfer case adapter kit on front
housing (33) with four socket head
screws (95).
(2)
Install lifting device on front housing (33).
(3)
Install front housing (33) and transfer case
adapter kit on holding fixture with four
screws (94).
(4)
Remove lifting device from front
housing (33).
TRANSFER
CASE
ADAPTER
KIT
LIFTING
DEVICE
33
HOLDING
FIXTURE
94
95
|