![]() TM 9-2330-385-14
4-8. PMCS TABLE (CONT).
Item
Interval
Item to Be
Procedure
Not Mission
No.
Inspected
Capable If:
1
Semi-
Cross-
Inspect crossmembers (1) and frame (2) for
Crossmembers or frame
Annual
members and
cracks in welds. If cracks are found, notify
have cracks in welds.
frame
Direct Support Maintenance.
2
Semi-
Drawbar
Check drawbar mounting bolts (1), tow ring
Tow ring diameter is less
Annual
mounting
mounting plate bolts (2), tow ring (3) and tow ring
than 1-1/4 in. (32 mm) or
bolts, draw-
bracket (4) for looseness, cracked welds or damage.
circumference is less
bar and draw-
Check tow ring (3) for wear by measuring in worn
than 4-5/8 in. (117 mm).
bar extension
area. If diameter is less than 1-1/4 in. (32 mm) or
Tow ring bracket bolt/
(if equipped)
circumference is less than 4-5/8 in. (117 mm),
nuts are loose or missing.
tow ring
replace tow ring prior to next mission. If any tow
bracket bolts,
ring bracket bolts/nuts are loose or missing, replace
Tow ring is loose or bent.
tow ring and
bolt/nut and tighten (Para 4-59 or Para 4-78). If
Tow ring has cracked
tow ring
looseness is found in tow ring, tighten (Para 4-59
welds.
bracket
or Para 4-78). If bending or cracked weld is found
in tow ring, replace (Para 4-59 or Para 4-78). If
Tow ring bracket lower
bending or gouging of lower lip of tow ring bracket
lip is bent or gouged.
is found, replace (Para 4-59 or Para 4-78). If dam-
age or looseness is found in drawbar mounting
bolts, notify Direct Support Maintenance.
4-8
|