TM 9-2330-385-14
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury, or death to personnel may occur.
CONTINUITY TEST
(1) Remove two screws and side marker
light lens.
(2) Remove light lamp.
(3) Set multimeter select switch to ohms.
(4) Is there continuity across light lamp?
(a) If there is no continuity, replace
lamp (Para 4-27).
(b) If there is continuity, lamp is OK.
VOLTAGE TEST
(1) Set multimeter select switch to
volts dc.
(2) Connect positive (+) multimeter lead
to center contact of socket.
(3) Connect negative (--) multimeter lead
to a known good ground.
(4) While assistant turns ON ENGINE
switch and turns on lights, observe
multimeter (TM 9-2320-364-10).
(a) If 22 to 28 vdc are not present,
perform Steps (5) and (6) below
and go to Step 5 of this Fault.
(b) If 22 to 28 vdc are present,
side marker light socket is OK.
(5) Turn off lights.
(6) Turn OFF ENGINE switch.
|