TM 9-2330-385-14
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury, or death to personnel may occur.
VOLTAGE TEST
(1) Disconnect LED composite light
ground wire pigtail from LED
composite light ground wire.
(2) Connect positive (+) multimeter lead
to LED composite light ground
wire pigtail.
(3) Connect negative (-) multimeter lead
to a known good ground.
(4) Set multimeter select switch to ohms.
(5) Is there continuity between LED
composite light ground wire pigtail?
(a) If there is no continuity, replace
LED composite light ground
wire pigtail (Para 4-29).
(b) If there is continuity, perform
Step (6) below and go to Step 4.1
of this Fault.
(6) Connect LED composite light
ground wire pigtail to LED
composite light ground wire.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |