![]() TM 9-2330-385-14
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury, or death to personnel may occur.
VOLTAGE TEST
(1) Disconnect wire 1008/21-29.
(2) Set multimeter select switch to
volts dc.
(3) Connect positive (+) multimeter lead
to center wire 1008/21-29 on wire
harness side.
(4) Connect negative (--) multimeter lead
to a known good ground.
(5) While assistant turns ON ENGINE
switch and turns on lights, observe
multimeter (TM 9-2320-364-10).
(a) If 22 to 28 vdc are not present,
perform Steps (6) through (8)
below and go to Step 5 of this
Fault.
(b) If 22 to 28 vdc are present, fault
not corrected, perform Steps
(6) and (7) below and replace
LED composite light (Para 7-29).
(6) Turn off lights.
(7) Turn OFF ENGINE switch.
(8) Connect wire 1008/21-29.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |