![]() TM 9-2330-385-14
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury, or death to personnel may occur.
VOLTAGE TEST
(1) Set multimeter select switch to
volts dc.
(2) Connect positive (+) multimeter lead
to center contact of socket.
(3) Connect negative (--) multimeter lead
to a known good ground.
(4) While assistant fully applies brake
pedal, observe multimeter
(TM 9-2320-364-10).
(a) If 22 to 28 vdc are not present,
release brake pedal and go to
Step (4) of this fault.
(b) If 22 to 28 vdc are present,
release brake pedal and go to
Step (3) of this fault.
CONTINUITY TEST
(1) Set multimeter select switch to ohms.
(2) Is there continuity between stoplight
socket ground and a known good
ground?
(a) If there is no continuity,
replace rear composite light
(b) If there is continuity, fault not
corrected. Perform Steps (3)
and (4) below and notify
supervisor.
(3) Install lamp in stoplight socket.
(4) Install preformed packing, composite
light cover, and six captive screws.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |