![]() TM 9-2330-385-14
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
CONTINUITY TEST
(1) Disconnect wire 1435 from nonoperating
LED composite light ground wire.
(2) Set multimeter select switch to ohms.
(3) Is there continuity between
wire 1435 connector and a known
good ground?
(a) If there is no continuity, repair wire
1435 (see schematic, Fig FO-1.1)
or replace rear side marker light
wire harness (Para 4-30.1).
(b) If there is continuity, replace
rear LED composite light
|