If air lines are disconnected when they are under 125 5 psi (862 34 kPa), they can whip around and
cause personal injury. Care should be exercised when disconnecting an air hose that is thought to be
under pressure.
VERIFY REPAIR
(1) Drain trailer air system (Para 2-21).
(2) Disconnect hose 2228 from air bag
control valve.
(3) Connect 0 to 160 psi (1103 kPa)
gage to air hose 2228.
(4) Start engine (TM 9-2320-364-10).
(5) While assistant pushes in trailer
charge valve in truck, observe
pressure gage (Para 2-22).
(a) If pressure does not raise to 125
5 psi (862 34 kPa), perform
Steps (6) through (10) below and
notify DS maintenance.
(b) If pressure does raise to 125
5 psi (862 34 kPa), fault
corrected.
(6) Pull out trailer charge valve in truck.
(7) Turn OFF ENGINE switch.
(8) Drain trailer air system.
(9) Disconnect gage from hose 2228.
(10) Connect hose 2228 to air bag
control valve.