TM 9-2330-385-14
4-15. AIR SYSTEM TROUBLESHOOTING PROCEDURES (CONT.)
2. ONE OR BOTH FLATRACK LOCKING MECHANISM LATCHES WILL NOT LOCK.
INITIAL SETUP
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
TM 9-2320-364-10
(Item 50, Appendix J)
Equipment Condition
Engine OFF, (TM 9-2320-364-10)
Materials/Parts
Parking brake applied, (TM 9-2320-364-10)
Solution, Soap (Item 21, Appendix E)
Wheels chocked, (TM 9-2320-364-10)
Emergency and service air supply gladhand
Personnel Required
Two
connected to truck, (Para 2-22)
Trailer air system charged, (Para 2-22)
Flatrack removed from trailer,
(TM 9-2320-364-10)
NOTE
Soap and water solution will be used to visually check for leaks.
START
1.
KNOWN INFO
TEST OPTIONS
Truck air system OK.
Are air lines 2078 and 2081,
Visual inspection.
and fittings free of crimps?
POSSIBLE PROBLEMS
REASON FOR QUESTION
Air lines and fittings faulty.
If air hose(s) is crimped, air
Flatrack locking valve faulty.
pressure will not exhaust from
Air chamber(s) faulty.
air chambers.
Flatrack locking mechanism
components faulty.
Repair or replace air
hose(s) and fitting(s)
(see schematic Fig
NO
FO-2 or Para 4-47).
Verify repair, go to
Step 5 of this Fault.
YES
|