Click here to make tpub.com your Home Page

Page Title: ONE OR BOTH FLATRACK LOCKING MECHANISM LATCHES WILL NOT UNLOCK OR REMAIN UNLOCKED. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2330-385-14
NOTE
125 5 psi (862 34 kPa) must be
S
supplied to trailer air system before
troubleshooting can begin.
Air lines and valves listed in this
S
troubleshooting procedure are illustrated
and located in FO-2.
VISUAL INSPECTION
(1) Push in flatrack locking valve
(2) Listen for leaks on following air lines
and components: air lines 2080,
2078, 2081, fittings, pressure
holdback valve, flatrack locking valve
and air chambers.
(a) If fittings leak and are loose,
tighten fittings.
(b) If air hose(s) leak, perform
Step (3) below and repair or
replace air hose(s) (see schematic
(c) If any of the components listed
above leak, perform Step (3)
below and replace them
according to maintenance
procedures (Chapter 4).
(d) If all of the Items above are OK,
perform Step (3) below and go to
Step (2) of this Fault.
(3) Pull out flatrack locking valve.
4-219

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business