![]() TM 9-2330-385-14
4-43. AIR RESERVOIR NO. 3 REPLACEMENT (CONT).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a well-
ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and
water.
Use sealing compound sparingly
and only on threads. Do not
apply compound on hose
connections. Damage to
equipment may result.
(5)
Apply sealing compound on threads on both
ends of fitting (16).
(6)
Install fitting (16) on air reservoir (12).
(7)
Apply sealing compound on threads of
elbow (15).
(8)
Install elbow (15) on fitting (16).
(9)
Apply sealing compound on threads of
elbow (15).
(10)
Install pressure hold back valve (14) on
elbow (15).
(11)
Apply sealing compound on threads of
fitting (9).
(12)
Install fitting (9) on pressure hold back
valve (14).
(13)
Apply sealing compound on threads of
elbow (10).
(14)
Install elbow (10) on air reservoir (12).
4-456
|