Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2330-385-14
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a well-
ventilated area. If adhesive,
solvent, or sealing compound gets
on skin or clothing, wash
immediately with soap and
water.
Use sealing compound sparingly
and only on threads. Do not apply
compound on hose connections.
Damage to equipment may result.
(15)
Apply sealing compound on threads of
reducer (6).
(16)
Install reducer (6) on air reservoir (12).
(17)
Apply sealing compound on threads of drain
valve (11).
(18)
Install drain valve (11) and cable (13) on air
reservoir (12).
(19)
Install air lines 2080 (7) and 2014 (8) on
fitting (9) and elbow (10).
(20)
Install air line 2606 (5) on reducer (6).
(21)
Install air line 2606 (5) on crossmember (4)
with clamp (3), screw (2) and locknut (1).
c.
Follow-On Maintenance:
Charge air system, (Para 2-22).
Check for air leaks, (Para 4-7).
Remove wheel chocks, (Para 2-20).
END OF TASK