![]() TM 9-2330-385-14
4-52. MULTIFUNCTION VALVE REPLACEMENT (CONT).
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors
and are harmful to skin and clothing. To avoid injury or death, keep away from open fire
and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or
clothing, wash immediately with soap and water.
Use sealing compound sparingly and only on threads. Do not apply compound on hose
connections. Damage to equipment may result.
(17)
Apply sealing compound on threads of
elbow (8).
(18)
Install elbow (8) on adapter (27).
(19)
Apply sealing compound on threads of
adapter (27).
(20)
Install adapter (27) on valve (20).
(21)
Apply sealing compound on threads of
fitting (16).
(22)
Install fitting (16) on valve (20).
(23)
Apply sealing compound on threads of
fitting (15).
(24)
Install fitting (15) on valve (20).
(25)
Position four washers (25), spacers (24),
washers (23) and mounts (22) on studs (26).
(26)
Apply sealing compound on top of four
studs (26).
(27)
Position multifunction valve (20) on
bracket (21) with four mounts (19),
washers (18) and locknuts (17).