TM 9-2330-385-14
5-13. REAR ELECTRICAL BOX REPAIR (CONT).
(b)
Remove wires (2) from resistor (3).
(c)
Remove nut (4) from resistor (3).
(d)
Remove resistor (3) and washer (5)
from hole (6) in cover (7).
(e)
Repeat Steps (a) through (d) for
remaining resistors (3).
(2)
Installation.
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors
and are harmful to skin and clothing. To avoid injury or death, keep away from open
fire and use in well-ventilated area. If adhesive, solvent, or sealing compound gets on
skin or clothing, wash immediately with soap and water.
NOTE
Replace cable ties as required.
(a)
Apply adhesive sealant around edge of resistor hole (6).
(b)
Apply sealing compound on threads of resistor (3).
(c)
Install resistor (3) and washer (5) on cover (7) with nut (4).
(d)
Slide two sections of heat shrink (1) over wires (2).
5-30