![]() TM 9-2330-385-14
(2)
Set multimeter select switch to ohms.
NOTE
Observe multimeter reading for
a measurement of 24.1 ohms
0.241 ohms. If measurement
is incorrect, replace resistor.
(3)
Connect positive multimeter lead to either
terminal of resistor (4).
(4)
Connect negative multimeter lead to
opposite terminal of resistor (4).
NOTE
Observe multimeter reading for
a measurement of 23.3 ohms
0.233 ohms. If measurement
is incorrect, replace resistor. If
measurement is correct, replace
circuit board.
(5)
Connect positive multimeter lead to either
terminal of resistor (5).
(6)
Connect negative multimeter lead to
opposite terminal of resistor (5).
b.
Resistor Replacement.
(1)
Removal.
NOTE
Tag and mark all wires prior
to removal.
Cut cable ties as required.
All resistors are removed the
same way.
Two different resistor values
are mounted on the box
cover, PH-25-24.1 and
PH-25-23.7. Locations of
these resistors are shown.
(a)
Remove heat shrink (1) from wires (2).