AC HEATER/EVAPORATOR BLOWER DOES NOT OPERATE - Continued
AC HEATER/EVAPORATOR BLOWER DOES NOT OPERATE - Continued

Air Conditioning System Nsn 4120-01-526-9158 P/N 3528349 For Truck, Tractor M1074/M1075 Palletized Load System Page Navigation
  38    39    40    41    42  43  44    45    46    47    48  
img
. . . . . . .
DRAFT
TB 9-2320-364-13&P-1
AC HEATER/EVAPORATOR BLOWER DOES NOT OPERATE - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
4.
KNOWN INFO
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Read WARNING on
TEST OPTIONS
CTIS operates indicating 24 vdc power OK.
page 0010-7.
Visual inspection.
AC circuit breaker OK.
Wire 1280A OK.
Are fan control switch and AC
REASON FOR QUESTION
heater/evaporator blower
Wire 1082 OK.
If connectors are loose or
motor resistor harness wires
Fan control switch OK.
wires are damaged, AC
free from damage and loose
heater/evaporator blower
POSSIBLE PROBLEMS
connectors?
will not operate.
Fan control switch harness connector loose
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
or faulty.
AC heater/evaporator blower motor resistor
harness connector loose or faulty.
Repair wires (see
AC heater/evaporator blower motor power
Appendix A) or
wire faulty.
replace fan control
AC heater/evaporator blower motor faulty.
switch harness
NO
(WP 0031) or AC
AC heater/evaporator blower motor ground
heater/evaporator
wire faulty.
blower motor resistor
YES
harness (WP 0036)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
as required. Verify
repair, go to Step 8 of
this fault.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
5.
KNOWN INFO
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Read WARNING on
TEST OPTIONS
CTIS operates indicating 24 vdc power OK.
page 0010-7.
Continuity test.
AC circuit breaker OK.
Multimeter.
Is continuity measured
Wire 1280A OK.
across AC heater/evaporator
Wire 1082 OK.
REASON FOR QUESTION
blower power wire from AC
Fan control switch OK.
If continuity is not measured,
heater/evaporator blower
Fan control switch harness connector OK.
AC heater/evaporator
motor resistor to blower
AC heater/evaporator blower motor resistor
blower power wire is
motor power wire splice?
harness connector OK.
faulty.
POSSIBLE PROBLEMS
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
AC heater/evaporator blower motor power
wire faulty.
Repair AC heater/
evaporator blower
AC heater/evaporator blower motor faulty.
NO
motor power wire (see
AC heater/evaporator blower motor ground
Appendix A) or replace
wire faulty.
AC heater/evaporator
blower motor resistor
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
YES
harness (WP 0036).
Verify repair, go to
Step 8 of this fault.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0010-6


Privacy Statement