TB 9-2320-364-13&P-1
AC HEATER/EVAPORATOR BLOWER DOES NOT OPERATE IN ALL SPEEDS
(LOW, MEDIUM, AND HIGH) - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2.
KNOWN INFO
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TEST OPTIONS
Fan control switch, fan control switch
harness, and AC heater/evaporator blower
Visual inspection.
resistor harness connections OK.
Does AC heater/evaporator
REASON FOR QUESTION
POSSIBLE PROBLEMS
blower motor operate in low,
If AC heater/evaporator
medium, and high fan control
AC heater/evaporator blower does not
blower operates in all
switch positions after
operate in all speeds.
blower speed switch
reseating loose connections?
positions, problem has
been corrected.
orange wire faulty.
Fan control switch harness orange wire faulty.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
brown wire faulty.
Fan control switch harness brown wire faulty.
Go to Step 3 of this
red wire faulty.
NO
fault.
Fan control switch harness red wire faulty.
AC heater/evaporator blower resistor faulty.
YES
Fan control switch faulty.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Go to Step 15 of this fault.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3.
KNOWN INFO
TEST OPTIONS
Visual inspection.
Fan control switch, fan control switch
harness, and AC heater/evaporator blower
REASON FOR QUESTION
resistor harness connections OK.
Does AC heater/evaporator
If AC heater/evaporator
blower motor operate in at
POSSIBLE PROBLEMS
blower operates in at least
least one fan control switch
AC heater/evaporator blower does not
one speed, power to fan
position (low, medium or
operate in all speeds.
control switch and AC
high)?
heater/evaporator blower
motor circuit is OK.
orange wire faulty.
Fan control switch harness orange wire faulty.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
brown wire faulty.
Fan control switch harness brown wire faulty.
NO
Evaporator Blower
red wire faulty.
Does Not Operate).
Fan control switch harness red wire faulty.
AC heater/evaporator blower resistor faulty.
YES
Fan control switch faulty.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0011-4