• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
AC HEATER/EVAPORATOR BLOWER DOES NOT OPERATE - Continued
AC HEATER/EVAPORATOR BLOWER DOES NOT OPERATE IN ALL SPEEDS (LOW, MEDIUM, AND HIGH) - Continued

Air Conditioning System Nsn 4120-01-526-9158 P/N 3528349 For Truck, Tractor M1074/M1075 Palletized Load System Page Navigation
  44    45    46    47    48  49  50    51    52    53    54  
img
. . . . .
DRAFT
TB 9-2320-364-13&P-1
0011
AC HEATER/EVAPORATOR BLOWER DOES NOT OPERATE IN ALL SPEEDS
(LOW, MEDIUM, AND HIGH)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Maintenance Level
Materials/Parts
Field Level Maintenance
None
Equipment Condition
Personnel Required
Shut off engine (TM 9-2320-364-10).
One
Parking brake applied (TM 9-2320-364-10).
References
Wheels chocked (TM 9-2320-364-10).
TM 9-2320-364-10
Tools and Special Tools
TM 9-2320-364-20
Tool Kit, General Mechanic's (Item 9, Appendix F)
Multimeter (Item 2, Appendix F)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
START
WARNING
1.
KNOWN INFO
TEST OPTIONS
Read WARNING on
None
Visual inspection.
page 0011-3.
POSSIBLE PROBLEMS
REASON FOR QUESTION
Are fan control switch, fan
Fan control switch, fan control switch
If fan control switch, fan
control switch harness, and
harness, or AC heater/evaporator blower
control switch harness,
AC heater/evaporator blower
resistor harness connections loose.
and AC heater/evaporator
motor resistor harness
blower motor resistor
AC heater/evaporator blower does not
harness connectors are
connections tight?
operate in all speeds.
not seated correctly, AC
AC heater/evaporator blower resistor harness
heater/evaporator blower
orange wire faulty.
may not operate at all
Fan control switch harness orange wire faulty.
switch positions.
AC heater/evaporator blower resistor harness
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
brown wire faulty.
Reseat loose
NO
connections and go
Fan control switch harness brown wire faulty.
to Step 2 of this fault.
AC heater/evaporator blower resistor harness
red wire faulty.
YES
Fan control switch harness red wire faulty.
AC heater/evaporator blower resistor faulty.
Fan control switch faulty.
Go to Step 3 of this fault.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
(0011-1 blank)/0011-2