4.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KNOWN INFO
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Read WARNING on
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Power to AC system OK.
page 0015-9.
TEST OPTIONS
AC heater/evaporator blower OK.
Visual inspection.
AC control circuit OK (except for temperature
control and low pressure switches).
Does AC condenser dryer
REASON FOR QUESTION
Low pressure switch OK.
sight glass indicate system is
No AC condenser dryer desiccant
If system is not fully charged,
fully charged?
contaminant in AC refrigerant system.
system may not cool
properly.
No AC refrigerant oil contaminant in AC
refrigerant system.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
POSSIBLE PROBLEMS
AC system charge low.
Perform leak test
AC system leaking.
(WP 0052). If leaks
Restricted AC hoses.
NO
are found, recover
AC compressor faulty.
R-134a refrigerant
(WP 0053), repair
Temperature control switch faulty.
leaks, and replace
AC expansion valve faulty.
YES
AC dryer (WP 0024).
Moisture in AC refrigerant system.
Charge system to full
Air or other contaminant in AC refrigerant
charge (WP 0053)
system.
and go to Step 5 of
AC condenser core faulty.
this fault.
AC system overcharged.
AC condenser dryer faulty.
AC evaporator core faulty.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0015-8