FIELD LEVEL MAINTENANCE INTRODUCTION - Continued
AC 20 AMP CIRCUIT BREAKER REPLACEMENT - Continued

Air Conditioning System Nsn 4120-01-526-9158 P/N 3528349 For Truck, Tractor M1074/M1075 Palletized Load System Page Navigation
  188    189    190    191    192  193  194    195    196    197    198  
img
. . . . . .
DRAFT
TB 9-2320-364-13&P-1
0018
AC 20 AMP CIRCUIT BREAKER REPLACEMENT
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
THIS WORK PACKAGE (WP) COVERS:
Removal
Installation
Follow-On Maintenance
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Maintenance Level
Materials/Parts
Field Level Maintenance
Tags, Identification (Item 10, Appendix E)
Lockwasher (Item 25, Figure 4, Appendix G)
Equipment Condition
Personnel Required
Batteries disconnected (TM 9-2320-364-20).
Electronic control box (ECB) cover removed
One
(TM 9-2320-364-20).
References
Tools and Special Tools
TM 9-2320-364-20
Tool Kit, Electrical (Item 8, Appendix F)
Tool Kit, General Mechanic's (Item 9, Appendix F)
REMOVAL
PLSAC015
NOTE
Tag and mark wires prior to removal to ensure proper installation.
1. Remove wire 1082 (1) from terminal (2).
2. Remove screw (3), lockwasher (4), and wire 1280A (5) from AC circuit breaker (6). Discard lockwasher.
3. Remove nut (7) and AC circuit breaker (6) from console (8).
0018-1