DRAFT
TB 9-2320-364-13&P-1
AC CONDENSER FAN MOTOR SOLENOID REPLACEMENT - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
PLSAC039
WARNING
Use extreme care when moving condenser to access solenoid. Failure to comply
may result in injury to personnel and/or damage to equipment.
Discard lockwashers.
NOTE
Tag and mark wires prior to removal to ensure proper installation.
7. Remove nut (13), lockwasher (14), and red wire (15) from terminal (16).
8. Remove nut (17), lockwasher (18), and green wire (19) from terminal (20).
9. Remove nut (21), lockwasher (22), and black wire (23) from terminal (24).
NOTE
Note position of solenoid prior to removal to ensure proper installation.
0026-4