AC CONDENSER FAN MOTOR SOLENOID REPLACEMENT - Continued
AC CONDENSER FAN MOTOR SOLENOID REPLACEMENT - Continued

Air Conditioning System Nsn 4120-01-526-9158 P/N 3528349 For Truck, Tractor M1074/M1075 Palletized Load System Page Navigation
  229    230    231    232    233  234  235    236    237    238    239  
img
DRAFT
TB 9-2320-364-13&P-1
AC CONDENSER FAN MOTOR SOLENOID REPLACEMENT - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
PLSAC039
WARNING
Use extreme care when moving condenser to access solenoid. Failure to comply
may result in injury to personnel and/or damage to equipment.
6. Remove four screws (9), lockwashers (10), washers (11), and cover (12) from condenser (7).
Discard lockwashers.
NOTE
Tag and mark wires prior to removal to ensure proper installation.
7. Remove nut (13), lockwasher (14), and red wire (15) from terminal (16).
8. Remove nut (17), lockwasher (18), and green wire (19) from terminal (20).
9. Remove nut (21), lockwasher (22), and black wire (23) from terminal (24).
NOTE
Note position of solenoid prior to removal to ensure proper installation.
10. Remove two nuts (25), lockwashers (26), black wire (27), and solenoid (28) from condenser (7).
0026-4