FRONT PIN LOCK AIR RELEASE WILL NOT OPERATE DURING LAUNCH OF BRIDGE BAY
WINCH ASSEMBLY WILL NOT WIND OUT

Parts Manual For Pallet, Adapter, Bridge M15 Page Navigation
  183    184    185    186    187  188  189    190    191    192    193  
img
.
TM 5-3990-263-13&P
0024
CORRECTIVE ACTION - Continued
2.
Disconnect and reconnect BAP air line quick-disconnect connector and ensure connector locks
(Figure 1).
a.
If locks do not work and/or an air leak is heard, notify Field maintenance.
b.
If front pin locks do not work during air-release procedure, manually release front locks to
deploy bridge bay. (WP 0008) Notify Field maintenance upon completion of mission.
END OF WORK PACKAGE