TM 9-2320-364-20-2
2-1626
50. 12 AND 24 VOLT SYSTEMS NOT CHARGING OR UNDER CHARGING
(145 AMP) (CONT).
Both voltmeters indicate low
charge.
Batteries OK.
Fuel pump operates indicating
24 vdc present at DUVAC
controller IGN terminal.
Alternator belts OK.
DUVAC controller OK.
Wire 1278 OK.
Jumperwire OK.
Alternator OK.
Wire 1344 OK.
Wire 1274 OK.
Brown wire OK.
Wire 1435 OK.
Black wire OK.
Red wire OK.
Orange wire OK.
Regulator OK.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Verify repair.
If voltmeters indicate proper
voltage, fault corrected.
YES
NO
Fault not corrected.
Notify Supervisor.
14.
Are the 12 and 24 vdc
charging systems charging
properly?
Fault corrected.
WARNING
Read WARNING
on Page 2-1627
|