TM 9-2320-364-20-3
2-2151
(1) Set multimeter select switch to ohms.
(2) Is there continuity between inflate
valve connector, terminal 1 and
rear manifold ground braid?
(a) If there is no continuity, replace
rear manifold (Para 13-9).
(b) If there is continuity, go to Step 26
of this Fault.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
|