TM 9-2320-364-20-3
2-2297
(1) Disconnect LHS control assembly
from harness connectors.
(2) Set multimeter select switch to ohms.
(3) Is there continuity between harness
connector MC83, terminal R and
LHS OVERLOAD lamp connector wire
1726 terminal?
(a) If there is no continuity, repair wire
1726 (see schematic Fig 2-52) or
notify DS Maintenance.
(b) If there is continuity, wire 1726
is OK.
(4) Install LHS control assy (Para 7-40).
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
|