TM 9-2320-364-20-3
2-2468
14. LHS DOES NOT UNLOAD IN AUTO MODE (CONT).
LHS operates in MAN HA
position.
LHS operates in MAN MF
position.
Proximity switch (hook arm up)
adjustment OK.
Wire 1485 OK.
Hydraulic selector switch OK.
Wire 1461 OK.
Wire 1435 OK.
Proximity switch (hook arm up)
OK.
Wire 1466 faulty.
LHS control assembly faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R #91.
If wire 1466 is loose, faulty or
shorted to ground, 22 to 28 vdc
will not be present at LHS
control assembly.
YES
NO
Repair wire 1466
(see schematic
Fig 2-52) or notify
DS Maintenance.
Verify repair, go to
Step 10 of this Fault.
8.
Is
continuity
measured on wire 1466 at
harness connector MC81,
terminal E and ground with
LHS junction box terminal 5
jumpered to ground?
7.
Replace proximity
switch (hook arm up)
(Para 7-38).
Verify repair, go to
Step 10 of this Fault.
YES
NO
LHS operates in MAN HA
position.
LHS operates in MAN MF
position.
Proximity switch (hook arm up)
adjustment OK.
Wire 1485 OK.
Hydraulic selector switch OK.
Wire 1461 OK.
Wire 1435 OK.
Proximity switch
faulty.
Wire 1466 faulty.
LHS control assembly faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If proximity switch is faulty, 22
to 28 vdc will not be present at
LHS junction box, terminal 5.
WARNING
WARNING
Are 22 to 28 vdc measured at
LHS junction box, terminal 5
with hook arm up and 0 vdc
measured with hook arm up?
Read WARNING
on Page 2-2469
Read WARNING
on Page 2-2469
|