TM 9-2320-364-20-4
7-208
7-56.
DDEC II ENGINE COLD PLATE/ELECTRONIC CONTROL MODULE
(ECM) REPLACEMENT (CONT).
(9)
Install two wiring harness connectors (20)
on ECM (14) and tighten two screws (19).
Use caution while installing
connectors from ECM. The
ECM has plastic retainers that
may break if connectors are not
properly installed.
NOTE
Ensure locking tangs are locked
in place when installing wiring
harness connectors.
(10)
Install three wiring harness connectors (18)
on ECM (14).
NOTE
If only installing cold plate,
perform Steps (11) and (12).
(11)
Install two preformed packings (16),
plate (17), plastic fitting block (8) and two
screws (15) on engine cold plate (12).
Tighten screws 84 to 108 lb-in (9 to 12
N.m).
(12)
Install engine cold plate (12) and six
screws (13) on electronic control
module (14). Tighten screws 156 to 204
lb-in (17 to 23 N.m).
|