TM 9-2320-364-20-5
18-16
18-4. CRANE REMOTE CONTROL BOX REPAIR (CONT).
b.
Cleaning/Inspection.
Drycleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles, face
shield, and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when using
solvent. The flashpoint for Type II Drycleaning Solvent is 140 degrees F (60 degrees C) and
Type III Drycleaning Solvent is 200 degrees F (93 degrees C). Failure to do so may result in
injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts
eyes, immediately flush eyes with water and get immediate medical attention.
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use only with
effective chip guarding and personal protective equipment (goggles/shield, gloves, etc).
Failure to comply may result in injury or death to personnel.
(1)
Clean all metal parts with drycleaning solvent.
(2)
Dry metal parts with compressed air.
(3)
Inspect for broken wires and connectors, cracks, and broken welds.
(4)
Replace all damaged parts.
c.
Assembly.
NOTE
Perform Step (1) only if data
plate was removed.
(1)
Install data plate (52) and ground terminal
(48) on box (2) with four rivets (51).
(2)
Position wiring harness (50) in box (2).
(3)
Install with ground wire (48) on ground
terminal (49).
|