TM 9-2320-364-20-5
20-4
20-2. MAIN HYDRAULIC PUMP DRIVESHAFT REPAIR (CONT).
Use care when removing retaining rings. Retaining rings are under spring tension and can act
as projectiles when released and could cause severe eye injury.
(11)
Remove two spring clips (10) from slip yoke (2). Discard spring clips.
(12)
Using a soft-faced hammer, drive U-joint (11) toward bearing cap (12) until it bottoms against slip
yoke (2).
(13)
Rotate slip yoke (2) 1/2 turn in vise.
(14)
Using a soft-faced hammer, drive
U-joint (11) toward bearing cap (13)
until it bottoms against slip yoke (2).
(15)
Separate slip yoke (2) from bracket (14)
and U-joint (11).
(16)
Using a punch, remove bearing caps (12)
and (13) from slip yoke (2). Discard
bearing caps.
(17)
Remove slip yoke (2) from vise.
Use care when removing
retaining rings. Retaining rings
are under spring tension and can
act as projectiles when released
and could cause severe eye injury.
(18)
Remove two spring clips (15) from
bracket (14) and U-joint (11).
(19)
Place bracket (14) and U-joint (11) in vise.
(20)
Using a soft-faced hammer, drive U-joint (11)
toward bearing cap (16) until it bottoms
against bracket (14).
(21)
Rotate bracket (14) 1/2 turn in vise.
(22)
Using a soft-faced hammer, drive U-joint (11)
toward bearing cap (17) until it bottoms
against bracket (14).
(23)
Remove U-joint (11) from bracket (14).
(24)
Remove bearing caps (16) and (17) from
bracket (14).
(25)
Remove bracket (14) from vise.
|