TM 9-2320-364-34-2
12-17
c.
Cleaning/Inspection.
Drycleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles, face
shield, and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when
using solvent. The flashpoint for Type II Drycleaning Solvent is 140 degrees F (60 degrees
C) and Type III Drycleaning Solvent is 200 degrees F (93 degrees C). Failure to do so may
result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts
eyes, immediately flush eyes with water and get immediate medical attention.
(1)
Clean all metal parts using drycleaning solvent.
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use only with
effective chip guarding and personal protective equipment (goggles/shield, gloves, etc).
Failure to comply may result in injury or death to personnel.
(2)
Clean rubber parts with a clean, dry cloth.
(3)
Inspect all parts for cracks, stripped threads and other signs of wear.
(4)
Replace all damaged parts.
d.
Assembly.
NOTE
Ensure vertical socket assembly
is installed as noted during
removal.
(1)
Install vertical socket assembly (10) on drag
link (3).
(2)
Tighten nut (13) on screw (12) 50 to 60 lb-ft
(68 to 81 N.m).
NOTE
Do not perform Steps (3) and (4)
if vertical socket assembly is lube
for life.
(3)
Install lube fitting (11) on vertical socket
assembly (10).
(4)
Install boot (9) on vertical socket
assembly (10).
(5)
Repeat Steps (1) through (4) for remaining
vertical socket assembly (10).
|